Fugitive Emissions Testing
Emissions standards for valves continue to tighten
up and to help meet the need for low fugitive emissions valves, United Valve
offers fugitive emissions testing, with both methane and helium, to a
sensitivity of two ppm. We can perform both production and design qualification
testing in our facility.
The primary document for qualification type fugitive emissions testing is
ANSI/ISA 93.00.01 “Standard Method for the Evaluation of External Leakage of
Manual and Automated Valves”. Production testing entails a number of open and
closed cycles (up to 5000), combined with a few thermal cycles at temperatures
up to 750oF (399oC). In addition to the ANSI document, United Valve can perform
fugitive emission tests to meet any customer specification or standard.
For
production tests not calling for the strict requirements of the ANSI document,
United offers helium fugitive emission testing. Our Varian helium leak detector
has a sensitivity of two ppm and is ideally suited to higher volume production
testing. We have performed fugitive emissions testing for both manufacturers and
end-users alike on valves from NPS ˝ through NPS 30.
|